← Troubleshooting Clinic

Case file · MOL-201

Intermediateabout 14 min10 effort available

No band from plant DNA

You are the postgraduate student running the PCR.

You extracted genomic DNA from young leaves of a woody tree using the CTAB method, and you want to amplify a 450 bp fragment of a nuclear gene. You set up 25 µl reactions with 1 µl of undiluted extract in each.

Four different trees were run, 30 cycles each. After the run you load all four reactions on a gel. Nothing shows in any of them. Your supervisor asks what you will test first. The thermocycler and the master mix are shared, and each repeat costs half a day.

The gel after the first PCR

A 1.5% agarose gel with the 100 bp ladder. Four lanes hold the reactions from trees 1 to 4. The fifth lane is the no-template control. There is no band at 450 bp in any lane, and no band anywhere else.

3000 2000 1500 1000 700 500 300 100 Ladder Tree 1 Tree 2 Tree 3 Tree 4 No template bp wells at the top, DNA runs downwards
No product at 450 bp in any of the four reactions, and the no-template control is also empty.

The reaction set-up

Each 25 µl reaction: buffer with 1.5 mM Mg²⁺, dNTPs, 0.3 µM of each primer, a hot-start polymerase, and 1 µl of undiluted extract. The extract is about 150 ng/µl, so each reaction held about 150 ng of template. Cycling: 95 °C for 3 minutes, then 30 cycles of 95 °C for 30 s, 56 °C for 30 s and 72 °C for 30 s, then 72 °C for 5 minutes. The lower primer Tm (melting temperature) is 56 °C.

Effort left 10of 10