Run the experiment, don’t just read about it
Each lab is an interactive bench. Change the settings, watch what happens, find out why a run goes wrong, then take the challenge with numbers that are different every time. Free, in your browser, no installation.
Gel electrophoresis lab
Pour, load and run an agarose gel. Choose the percentage, voltage and time, find out why bands smear or run off the end, then size unknown fragments against a ladder.
- Choosing agarose %
- Reading a ladder
- Sizing fragments
- Spotting a bad run
Culture medium designer
Pick an explant of a tobacco plant, design its culture medium (auxin, cytokinin, sugar, gel, light), and see the jar after four weeks: shoots, callus, roots, browning or glassy vitrified shoots.
- Auxin to cytokinin ratio
- Molar doses from mg/L
- Shoots, callus or roots?
- Diagnosing vitrification and browning
Greenhouse climate control lab
Run a small greenhouse through a whole day of weather. Set the vents, shade, fogging, heating and night screen, then watch the temperature, humidity, vapour pressure deficit and light the crop really gets.
- Reading VPD, not just RH
- Ventilation and shading
- Evaporative cooling and its limit
- Light and the daily light integral
- Vent-and-heat on a damp night
Irrigation and substrate water lab
Water a pot for fourteen days. Choose the substrate, the crop and the irrigation schedule, then watch the water content, the air, the drainage and the salt in the root zone.
- Container capacity and air space
- Readily available water
- Pulse irrigation and sensors
- Leaching fraction and EC build-up
- Choosing a substrate for a pot
PCR designer and thermocycler
Design a primer pair on a template, set the thermocycler programme, watch the cycles run, and read the result on a gel. Then rescue a PCR that failed with as few changes as you can.
- Primer design checks
- Setting annealing and extension
- Exponential yield and the plateau
- Troubleshooting no band, smear, extra bands and primer-dimers
Grow-light designer
Hang fixtures over a growing bench. Choose the height, the number of fixtures and the colour mix, then read the light map, the daily light integral, the electricity and how the plants will grow.
- Daily light integral (DLI)
- Inverse-square and cosine fall-off
- Uniformity (min / average)
- Fixture efficacy and electricity per mole
- Red:far-red, blue share and plant shape
- Photoperiod and night breaks
qPCR explorer
Watch amplification curves on a real-time plot, set the threshold, build a dilution-series standard curve, turn Ct values into a fold change with ΔΔCt, and read melt curves and no-template controls.
- Threshold and baseline
- Standard curve and efficiency
- ΔΔCt and the Pfaffl correction
- Reference gene stability
- Melt curves and NTC controls
Experiment design simulator
Set up an experiment on a bench, run it, then run it a thousand times. See power, false positives, bias from a gradient, the damage done by pseudoreplication and the gain from randomising and blocking.
- Replicates and power
- Randomisation
- Blocking
- Spotting pseudoreplication
- Choosing the cheapest valid design
Nutrient solution mixer
Weigh stock salts into a tank, watch each element climb towards its target, neutralise the bicarbonate in your water with acid, and keep the calcium apart from the sulphate. Then read sick leaves and find the cause.
- mmol, meq and mg per litre
- Salts as weighed (hydrates)
- What the water already supplies
- Alkalinity, acid and pH
- EC from the cations
- Gypsum and stock A and B
- Nitrogen form and root-zone pH
- Mobile and immobile nutrients
- Reading deficiency symptoms
Crossing and selection simulator
Make crosses and watch Mendel's ratios appear from random draws, test them with chi-square, run a backcross programme chromosome by chromosome, and see how selection moves a population mean and uses up its variation.
- Mendelian ratios and chance
- Chi-square test
- Sample size
- Backcrossing and genome recovery
- Linkage drag
- Marker-assisted selection
- The breeder's equation R = h² S
Seed germination and viability lab
Run a standard germination test on four dishes of 100 seeds, read tetrazolium stains, predict how long seed will keep, and find out which treatment releases which kind of dormancy.
- Standard germination test
- Normal and abnormal seedlings
- Replicate tolerance
- Reading tetrazolium
- Dormancy versus death
- Harrington's rules
- Accelerated ageing
- Releasing dormancy
ELISA plate reader
Design a 96-well plate with standards, blanks and controls, watch the colour develop, then read the optical densities, fit a standard curve, set a cut-off and call each sample positive or negative.
- Plate layout and controls
- Blank, cut-off and CV
- Standard curve and saturation
- Edge effects and poor washing
- Cross-reaction and false positives
Sterilisation and contamination lab
Run an autoclave and watch the centre of the bottle lag behind the chamber, find the bleach and contact time that clean an explant without killing it, then see how habits at the cabinet change contamination in a batch of 100 vessels.
- D-value, z-value and F0
- Heating lag and the coldest point
- Sterility assurance (log reduction)
- Disinfectant window: kill against damage
- Aseptic technique and contamination per transfer
Consignment inspection sampling
Hide a pest in a consignment, choose how many units to inspect and how to pick them, and see the chance of finding it, why a clean sample proves less than it seems, and what clustering and convenience sampling do.
- Sample size from prevalence and confidence
- Random and representative sampling
- Clustered infestation
- Imperfect detection
- Residual risk of a clean sample
Scouting and spray-decision simulator
Scout a bench of 100 plants for eight weeks. Choose how many plants to inspect and which, compare what the sample says with the true pest numbers, and decide each week: nothing, release natural enemies, spray or remove plants.
- Economic injury level and action threshold
- Degree-days and pest growth
- Sampling error and biased samples
- Natural enemies and the predator ratio
- Resurgence and resistance after sprays
- Evaluating a season
Microscope set-up and resolution
Set up a virtual microscope: choose the objective, set Köhler illumination and the condenser aperture, focus, and pick brightfield, phase contrast or fluorescence with the right filters. Watch resolution, contrast and bleaching change the picture.
- Resolution, NA and wavelength
- Köhler illumination and the condenser aperture
- Choosing a contrast method
- Matching fluorescence filters
- Depth of field, focus and bleaching
Labs are teaching models: they show how the variables behave. Your own equipment and material will differ, so follow your lab’s validated procedure. Your challenge results are private to you.