ELISA plate reader
Lay out a plate, develop it and read it. Then do what a diagnostic lab does: check that the controls are valid, set the cut-off from the negatives, and decide which samples carry the virus.
Loading the lab…
About this model
In a double-antibody sandwich ELISA the amount of yellow colour (optical density, OD, at 405 nm) rises with the amount of antigen in the well. A buffer blank (no extract) shows the colour from the substrate and plastic alone. Healthy-plant negative controls give the cut-off, mean + 3 standard deviations, as in lesson 3.3: samples below it are negative, samples more than 10% above it are positive, and readings in between are borderline and should be retested. A positive control must read clearly above the cut-off; if it does not, the plate is not valid. Duplicate wells let you calculate a coefficient of variation (CV = SD ÷ mean); duplicates that disagree by more than about 15% point to a pipetting error.
Calibration: the model reproduces the lesson’s numbers, healthy extract reading about 0.10 with an SD of about 0.016, a buffer blank near zero and the three worked cut-offs (0.147, 0.177 and 0.107, checked in the unit tests). Assumptions that the lessons do not give, chosen for teaching: a four-parameter (S-shaped) standard curve with its half-way point at 30 ng/mL and its top at an OD of 2.4; standards diluted three-fold from 300 ng/mL in healthy extract, so the zero standard is the negative control; readings above 2.0 are treated as saturated and left out of the curve; edge wells of an unsealed plate read 20% high; washes remove unbound enzyme-labelled antibody by a factor of five each time; a blank above 0.10, negatives with an SD above 0.04, or a positive control under twice the cut-off make a plate invalid; duplicates above 15% CV are flagged where the OD is above 0.30; a related virus gives 8% of the signal of the target. These effect sizes are teaching choices, not measurements of a particular kit.
Positive results in a healthy-looking plant could be a cross-reaction with a related virus, so important positives are confirmed by a second, independent method such as PCR (lesson 4.1).
Calibrated against: PDD-301 lesson 3.3 (serology, cut-off from negative controls; the three worked examples are reproduced in the unit tests); PDD-301 lesson 4.1 (confirming serological positives); Clark and Adams 1977, Journal of General Virology 34: 475 (double-antibody sandwich ELISA); Findlay and Dillard 2007, AAPS Journal 9: E260 (four-parameter curve fitting for immunoassays).
This is a teaching model. It shows how the variables behave and what to expect; your own instruments, reagents and material will differ, so always follow your lab's validated procedure.
Related lessons: Serology: ELISA and lateral flow (PDD-301 lesson 3.3),Evidence and confirmation (PDD-301 module 4)