A medium is only sterile if its coldest spot got enough heat for long enough, and an explant is only clean-and-alive inside a narrow window of disinfectant. Work through the three parts and find out what really protects a culture.

Loading the lab…

About this model

Autoclave. Spores die in a log-linear way, so the number of log reductions is time divided by D (lesson 2.1 of TCL-201: D121 = 1.5 min for the reference spore, and D falls tenfold for every 10 C rise, z = 10 C). Lethality is F0 = the sum of 10^((T - 121.1)/10) x dt over the whole run, in equivalent minutes at 121.1 C, and the log reduction is F0 divided by D121 (as in the lesson, which ignores the 0.1 C difference). The load centre follows the chamber with a first-order lag. The lag constant is 2.7 min for the 0.5 L bottle of the lesson's probe record, and grows with the fourth root of the volume so that a 4 L bottle needs about 20 min to catch up (PTC-101 lesson 2.4). The chamber warming at 12 C per minute, the exhaust speeds (the chamber cools with a time constant of 8 minutes on slow exhaust, which reproduces the lesson's probe cool-down, and 1.5 on fast), and the slowing factors for crowded loads (1.15, 1.4 and 2 times) are teaching assumptions: the lessons say a densely packed load slows the steam but give no figure.

Heat damage to the medium is shown as a cook value, the number of minutes at 100 C that would do the same damage, where damage speeds up tenfold for every 33 C (z = 33 C, the usual value for the loss of heat-sensitive quality in food-processing textbooks). The lessons only say that long heating breaks down sucrose, vitamins and hormones, so this is a teaching index for comparing cycles, not a measurement. Because spores have a small z (10 C) and quality has a large one (33 C), a hotter and shorter cycle kills the same number of spores with less damage, which is the lesson's own advice.

Surface disinfection. Kill and damage follow dose = bleach percentage x minutes. The curves are fitted to the five treatments in the PTC-101 lesson 4.2 table (0.5 to 2% for 10 or 15 min): contamination falls by one log for each 10 units of dose and levels off at a floor of about 3% (endophytes inside the tissue, which more bleach cannot reach), and tissue death follows a log-normal curve with its middle at a dose of about 25. Ethanol is a pre-dip: the lessons give only the 30 to 60 s time and that 70% works better than absolute ethanol, so the extra dose each option adds is an assumption. Wetting agents and bleach pH are not modelled. Every species and tissue has its own window, so the lab varies how dirty the material is and how tender it is.

Laminar flow technique. The starting rate is 2% contamination per transfer, the figure of the lesson's worked example; each poor habit multiplies it by a factor. The lessons name these habits and say they raise contamination (PTC-101 lesson 2.3, TCL-201 lessons 3.3 and 3.4) but give no sizes, so the factors are illustrative: they show direction and rough rank, not measured values. Treating an instrument tip between transfers (very hot and brief, surface only, cooled before use) is described in lesson 2.2 as a way to keep working, not a substitute for autoclaving; the lab does not rank flame against bead units or give effectiveness figures for them. Over several transfers the chance of staying clean is (1 - p) raised to the number of transfers, as in the lesson.

Calibrated against: TCL-201 lessons 2.1, 2.4, 3.2 to 3.4 (D, z, F0, 121 C worked probe record, window, particles); PTC-101 lessons 2.3, 2.4 and 4.2 (cabinet technique, 4 L bottle lag, bleach table); Holdsworth and Simpson, Thermal Processing of Packaged Foods (cook value, z of 33 C); Pflug, Microbiology and Engineering of Sterilization Processes (F0 and D-values).

This is a teaching model. It shows how the variables behave and what to expect; your own instruments, reagents and material will differ, so always follow your lab's validated procedure.

Related lessons: Sterilisation in TCL-201,Clean air in TCL-201,Initiation and bleach in PTC-101