← Virtual labs

HL-20125 minCore skill

Grow-light designer

A plant counts the photons it gets in a whole day, and it reads the colour and the length of the day as signals. Design the light, see where the dim spots are, and find out what it costs in electricity.

Loading the lab…

About this model

Each fixture is a wide-beam source whose light on the canopy follows E = E0 h^4 / (h^2 + x^2)^2 (lesson 4.3 of HL-201). Scaled so that the beam sends all of a fixture's photons into the lower half-space, the light directly beneath is the photon output divided by pi h^2; added together for every fixture, this gives the PPFD in each 10 cm square of the bench. Uniformity is the lowest square divided by the average (lesson 1.4). The DLI is PPFD x hours x 3600 / 1,000,000 (lesson 3.3), and the electricity is the photons you need divided by the fixture's efficacy (lessons 4.1 and 5.1).

The fixture mixes four kinds of LED. Red and blue LEDs turn 55% of their electricity into radiant light (lesson 4.2) and a photon of 660 nm or 450 nm carries 5.5 or 3.8 micromoles per joule (lessons 2.3 and 5.4), which gives 3.0 and 2.1 micromoles per joule of electricity. A white LED gives 20% blue, 45% green and 35% red (lesson 1.3). Far-red (730 nm) costs electricity but is outside the 400 to 700 nm that PPFD counts. The plant panel uses only the thresholds the lessons teach: R:FR about 1.15 in sunlight and 0.1 to 0.5 under a canopy (lesson 2.2); 5 to 15% blue (lesson 2.3); "signals cannot replace missing carbon" (lesson 2.4); the DLI bands of GH-101 lesson 2 (seedlings 6 to 12, lettuce and herbs 12 to 17, pot flowers 10 to 20, tomato 20 to 30); tomato injured by 24 hours of light (lesson 3.3); and a short-day plant needing about 11 hours of unbroken dark, with a night break that cuts the night in two (GH-101 5.1 and HL-201 6.2).

What is assumed rather than taken from a lesson: each fixture draws 100 W at full output and keeps its efficacy when dimmed; white LEDs convert 47% of their electricity to light (the lessons say only that they are less efficient than red and blue); white reflective side walls return 80% of the light that reaches them (lesson 4.3 names reflective walls but gives no figure); fixtures cannot hang closer than 30 cm; a fixture is a point source; and the long-day plant uses the same 11 hour critical night as the lesson's short-day example. The model does not say how much a plant will grow: it says which way the signals push it, as the lessons do.

Calibrated against: HL-201 lessons 1.3, 1.4, 2.2, 2.3, 2.4, 3.3, 4.1, 4.2, 4.3, 5.1, 5.4 and 6.2 (the worked examples are reproduced in the unit tests); GH-101 lessons 2 (DLI needs of crop groups) and 5.1 (photoperiod and flowering).

This is a teaching model. It shows how the variables behave and what to expect; your own instruments, reagents and material will differ, so always follow your lab's validated procedure.

Related lessons: Horticultural lighting in HL-201,Greenhouse crop production in GH-101