Greenhouse climate control lab
Pick a day of weather and manage the house. Every choice has a price: shade cools the house but also takes light, fogging cools dry air but wets humid air, and closing the vents at night saves heat but traps moisture.
Loading the lab…
About this model
The house is treated as one box of air above a floor, with every flow counted per square metre of floor. Sunshine comes through the cover (75% gets in) and is shared between warming the air, evaporating water from the crop (a well-watered crop turns about half of the absorbed sun into latent heat) and heating the floor. Heat leaves through the cover (U = 4 W/m2K on 1.4 m2 of cover per m2 of floor) and by ventilation, using Q = density x specific heat x airflow x temperature rise. Water vapour is balanced the same way, so humidity, temperature and VPD always agree with each other.
Saturation vapour pressure uses the Tetens formula, e = 0.6108 exp[17.27 T / (T + 237.3)] kPa, which gives 2.34 kPa at 20 C and 3.17 kPa at 25 C, as in the lesson. A pad cools the air towards its wet-bulb temperature (pad efficiency 75%) and the evaporated water is added to the air, so cooling and humidity rise together. Light is 46% of the sun's energy, converted at 4.57 micromoles per joule, and the daily light integral is the sum of the day's PPFD. The plant bands are the lesson's: VPD under 0.3 kPa is too wet, 0.5 to 1.2 is the usual day target and above about 1.5 the pores begin to close; chilling below 10 C and heat stress above 32 C are teaching values for a warm-season crop such as tomato or cucumber.
What is assumed rather than taken from a lesson: the heat capacity of the house, a floor layer that stores some sun by day and returns it at night, how fast transpiration responds to VPD, how much air a closed night screen lets through, and the made-up weather (seeded, so the same seed gives the same day). Real houses differ in size, cover and crop, so use the lab for how the pieces push on each other, not for design numbers.
Calibrated against: GH-101 lessons 1.1 to 1.4, 2.1 to 2.3 and 3.1 to 3.4 (worked examples reproduced in the unit tests); Tetens / Magnus saturation vapour pressure (FAO-56 form); McCree, quanta per joule of PAR.
This is a teaching model. It shows how the variables behave and what to expect; your own instruments, reagents and material will differ, so always follow your lab's validated procedure.
Related lessons: Greenhouse crop production in GH-101